MMC Calculator  Ver. 2.2   9/12/2000  Terry Fritz
Transformer voltage =  15000 
Transformer current =  .06 
Firing voltage =  21213.15 
Fo =  85000 
Break rate =  120 
Thermal dissipation constant =  40 
Individual cap value =  5.6E-08 
 
Strings  Caps/Str  Capacitance  Voltage   Temp C    Cost              I Arms
  1        2         28.00         3200   192.83    2.90  :-((  :-((  13.65 
  2        4         28.00         6400    48.21   11.60  :-((  :-((  13.65 
  3        6         28.00         9600    21.43   26.10  :-((  :-((  13.65 
  4        8         28.00        12800    12.05   46.40  :-((  :-|   13.65 
  5       10         28.00        16000     7.71   72.50  :-((  :-)   13.65 
  6       12         28.00        19200     5.36  104.40  :-|   :-)   13.65 
  7       14         28.00        22400     3.94  142.10  :-))  :-))  13.65 
--------------------------------------------------------------------
  8       16         28.00        25600     3.01  185.60  :-))  :-))  13.65 
  8       17         26.35        27200     2.67  197.20  :-))  :-))  12.85 
  9       18         28.00        28800     2.38  234.90  :-))  :-))  13.65 
  9       19         26.53        30400     2.14  247.95  :-))  :-))  12.94 
 10       20         28.00        32000     1.93  290.00  :-))  :-))  13.65 