AR7030 infrared control information:

   NEC protocol 16 bit
   Address 026 HEX

I.R key                Hex value

1                      0C
2                      11
3                      12
4                      10
5                      19
6                      1A
7                      18
8                      1D
9                      1E
0                      15

. DECIMAL              16
CLEAR                  13
BACKSPACE              1C
kHz                    17
MHz                    1F

CW/NFM                 8
LSB/USB                0D
AM/SYNC                0E

+ MODIFY               2
- MODIFY               6

TUNE UP                3
TUNE DOWN              7

VOLUME UP              0B
VOLUME DOWN            0F

PASSBAND MODIFY        0
FILTER MODIFY          1
BASS MODIFY            5
TREBLE MODIFY          14

VFO SELECT A/B         0A

MEMORY STORE           4
MEMORY PREVIEW         9
MEMORY RECALL          1B
